The Aquacounter Volumetric Karl Fischer Titrator MOIVO-A19 is the perfect solution for scientists and professionals needing reliable, accurate water content analysis. It features a compact design with state-of-the-art technology to provide precise results from 0.01 to 100%. Get quick, accurate results with the touch of a button and save valuable lab space at the same time.
The Aquacounter MOIVO-A19 is manufactured in Japan and replaces the Aquacounter AQV-2200 series.
Features
Large color touch panel LCD
Largest 8.4 inch screen in its class. It is easy to input characters on the touch panel, and each operation can be performed intuitively from the menu screen. A protective film that can be replaced to prevent scratches and stains.
16 levels of angle adjustment for liquid crystal display
We provide the best experience for each user. Since the angle is locked, it will not fall down even if you push it.
Audible Notifications
Audio notifies you of the end of measurement, errors, and reception from the balance. This makes it easier to check even from a distance.
Simultaneous measurement of up to 4 types
By adding a titration station, it is possible to simultaneously measure up to four types of moisture measurement and titration.
Built-in thermal printer
Equipped with a thermal printer with a paper width of 58 mm. It can be set easily by inserting the roll paper and closing the cover. The information you want to know is clear at a glance with English printing.
USB/LAN connector
Approximately 9,900 results can be stored on a USB memory stick. With optional software, the user can view the data on a PC or use a recalculation function. With a LAN connection, the user can also view the data on a Web browser.
User Authentication Settings
You can limit the users who can use it, which improves security and prevents unintended changes in measurement conditions.
Status display by 3-color LED
You can check the operating status from a remote location. You can immediately notice sudden troubles.
Easy replacement of burette head
To remove, simply pull forward. Reagent bottles can be replaced with one hand.
Economy purge function
Repeat discharge and suction at the upper end of the syringe. Reagent replacement work can be automated, and waste liquid can be greatly reduced. The number of economy purges can be set from 1 to 99 times.
Reagent back-up function
Don't waste expensive Karl Fischer reagents.
Forty Rotation Speeds
The manually set speed is easy to see and understand with the bar display of 10 LEDs. (4 steps per scale)
2-color LED display for operating status
You can check the operating status from a remote location.
Manual feeding/discharging unit
A manual pump can be used to supply and dispense reagents. The titration cell is also configured with a drain cock. In that case, the manual feeding/discharging unit is not included. Small volume titration cell with low running cost. The amount of titration solvent used is 2/3 of the conventional amount. Reagent-saving also leads to reduction of waste liquid and running cost. Since the surface area and volume in the cell are small, blanking before the start of measurement is quick.
Specifications
Measurement method | Karl Fischer Volumetric Titration |
---|---|
Simultaneous measurement function | Simultaneous measurement of up to 4 types of moisture content (coulometric method/volumetric method) and titration (with optional expansion unit) |
Titration control method | Continuous dripping and intermittent dripping control only near the end point |
End point detection method | AC polarization current detection method, AC polarization potential difference detection method |
range of measurement | 0.1 mg H2O to 500 mg H2O (10 ppm to 100%) |
background correction | Automatic correction (can be set with or without correction) |
burette | Accuracy rate: Within ±0.1% (When discharging the full capacity of 20mL burette (new)) Repeatability: Within 0.01mL (When discharging the full capacity of 20mL burette, standard deviation of n = 6) |
connecting tube | φ2×φ3 PTFE tube |
valve switching | Automatic switching by ceramics ground valve |
Minimum drop amount | 0.005mL, 0.01mL, 0.02mL, 0.05mL switching setting |
titration cell | Standard titration cell: 150 mL (minimum volume of liquid used: approx. 30 mL) Small volume titration cell: 75 mL (minimum volume of liquid used: approx. 20 mL) or more |
Display method | 8.4 inch color touch panel liquid crystal display |
display unit | mL ( minimum display 0.001 mL), mgH2O , %, ppm |
calculation function | Concentration calculation, titration calculation, back titration calculation, recalculation, statistical calculation |
file function | Measurement condition files (measurement condition files according to the sample): 51 files Sample files (reservation setting files for sampling amount): 99 files Measurement sequence files for EV: 51 files |
Number of data storage | Main unit memory: 100 data/channel (*) Depending on the capacity of 1 data (such as when there is a large amount of data for each elapsed time), this number of data may not be reached. |
GLP-compliant functions | (1) Reagent management 1. Remaining amount of burette, replacement date, and replacement alarm2 . Total discharge volume of burette and date of start of use3 . Indicator electrode replacement date (2) Measurement accuracy test (3) Burette accuracy test (4) User management function |
Manual feeding/discharging unit | attached |
printer | Built-in thermal printer (roll thermal paper width 58mm) Dot impact printer PR-302B (roll plain paper width 58mm) can be connected (Optional) |
External input/output | [MC-3000] RS-232C: 1 port for balance or HOST LAN: 1 port USB: 1 port (dedicated for USB memory) [TQV-3000] RS-232C: 1 port for communication with evaporator |
power supply | AC100-240V±10% 50/60Hz 110VA |
size and weight | MC-3000: 235W x 400D x 250H (mm) Approx. 5.0kg TQV-3000: 120W x 340D x 500H (mm) Approx. 5.5kg (including burette head) K-3000A: 100W x 165D x 175H (mm) Approx. 1.5kg Manual supply/discharge unit: 180W x 260D x 300H (mm) Approx. 1.2kg |
Optional Accessories
- Dot impact printer PR-302B
- Coulometric moisture measurement extension unit TQ-3000S/F/E (with K-3000A stirrer)
- Volumetric moisture measurement expansion unit TQV-3000S/E (with K-3000A stirrer)
- Titration Station TS-3000
- Stirrer K-3000T (for titration)
- Moisture vaporizer EV-2000
- Moisture vaporizer for lubricating oil EV-2000L
- Automatic Heating and Moisture Vaporizer EV-2010
- Automatic Heating and Moisture Vaporizer SE-320